Laboratoire de métrologie à
Newark, New Jersey

HORAIRES D'OUVERTURE

Lun
07:00 - 04:30
Mar
07:00 - 04:30
Mer
07:00 - 04:30
Jeu
07:00 - 04:30
Ven
07:00 - 04:30
Contacts
(973) 299-2950
2 Mars Ct.
Boonton, NJ 07005

ACCRÉDITATION

ISO/IEC 17025

ANSI/NCSL Z540.1-1994

ANSI/NCSL Z540.3-2006

Scope of accreditation
A2LA Cert #2553.01

A2LA Cert #2553.01

ISO/IEC 17025

ISO/IEC 17025

ANSI/NCSL Z540.1-1994

ANSI/NCSL Z540.1-1994

ANSI/NCSL Z540.3-2006

ANSI/NCSL Z540.3-2006

DOMAINES TECHNIQUES

Compétence accréditée
Compétence non accréditée
Accélérométrie
Dimensionnel
Électricité / Magnétisme
Force
Hygrométrie
Mass / Scale
Pressure / Vacuum
Température
Couple
Time / Frequency
Accélérométrie

Accélérométrie

Compétence accréditée

Global Calibration Scope

  • 100 mV/G Freq Response: 5 hz to 10 kHz

Common equipment serviced: Accelerometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensionnel

Dimensionnel

Compétence accréditée

Global Calibration Scope

  • Micrometers and Calipers up to 40 “
  • Rulers up to 36”
  • Height and depth gauges up to 40 “
  • Pins and Dial Indicators up to 2 “

Common equipment serviced: Hand tools: Calipers, micrometers, indicators, height gauges, rulers & tapes

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Électricité / Magnétisme

Électricité / Magnétisme

Compétence accréditée

Global Calibration Scope

  • AC/DC Voltage Generation up to 1100 V
  • Measurements up to 160 kVdc and 100 kV ac.
  • Electrical temp simulation: RTD, TC
  • Current Generate up to 30 Amps/1025 A (w/ coil)
  • Power (AC+DC) up to 30.8 kW
  • Resistance 1 mOhm up to 10 TOhms
  • Generate /measure signals up to 50 GHz.
  • Absolute Power from -70 to +20 dBm.
  • Phase Modulation up to 26.5 GHz.
  • Phase Generate 0 to 90 º (up to 30 kHz)
  • Phase measure 0 to 359.9 º (up to 500 kHz)
  • Distortion 20 hZ to 26.5 GHz.

Common equipment serviced:

DC/LF: Multimeters, Oscilloscopes, LCR Meters, Oscilloscope/meter probes, Power supplies, Loads, Safety Testers, Resistance Meters, clamp meters, Hipots, panel meters, etc.

HF/RF/Microwave Signal Generators, Spectrum analyzers, power meters, function generators, power sensors, and Distortion analyzers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Force

Force

Compétence accréditée

Global Calibration Scope

  • Force gauges : up to 500 lbs class 6 & F weights

Common equipment serviced: Force gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Hygrométrie

Hygrométrie

Compétence accréditée

Global Calibration Scope

  • Generate: +/-1.4% RH from 10 to 90% RH

Common equipment serviced: RHT Meter/probes, psychrometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Mass / Scale

Mass / Scale

Compétence accréditée

Global Calibration Scope

  • Scales: up to 500 lbs class 6 & F weights
  • Balances up to 55 kG Class 1&3 Weights

Common equipment serviced: Balances, Scales

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pressure / Vacuum

Pressure / Vacuum

Compétence accréditée

Global Calibration Scope

  • Measure:Pneumatic -14.6 to 1000 psig
  • Measure: Hydraulic: 10 to 10000 psig

Common equipment serviced: Calibrators, pressure gauges, sensors/transmitters, barometers, pressure sensors, manometers, Etc.

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Température

Température

Compétence accréditée

Global Calibration Scope

  • Measuring range : -195 ºC to 420 ºC w/ SPRT
  • Range of 35 to 500 ºC for IR Thermometers

Common equipment serviced: Temperature baths, chambers, ovens, calibrators, Temperature probes, IR thermometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Couple

Couple

Compétence accréditée

Global Calibration Scope

  • 20 ozf-in to 200 ozf-in.
  • 4 lbf-in to 600 lbf ft.

Common equipment serviced: Torque wrenches, screwdrivers, watches

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Time / Frequency

Time / Frequency

Compétence accréditée

Global Calibration Scope

  • Measure and Generate frequencies up to 50 GHz
  • Tachometers up to 100,000 RPM.

Common equipment serviced: Counters, Stopwatches, Timers, frequency generators, tachometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Accélérométrie

Global Calibration Scope

  • 100 mV/G Freq Response: 5 hz to 10 kHz

Common equipment serviced: Accelerometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensionnel

Global Calibration Scope

  • Micrometers and Calipers up to 40 “
  • Rulers up to 36”
  • Height and depth gauges up to 40 “
  • Pins and Dial Indicators up to 2 “

Common equipment serviced: Hand tools: Calipers, micrometers, indicators, height gauges, rulers & tapes

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Électricité / Magnétisme

Global Calibration Scope

  • AC/DC Voltage Generation up to 1100 V
  • Measurements up to 160 kVdc and 100 kV ac.
  • Electrical temp simulation: RTD, TC
  • Current Generate up to 30 Amps/1025 A (w/ coil)
  • Power (AC+DC) up to 30.8 kW
  • Resistance 1 mOhm up to 10 TOhms
  • Generate /measure signals up to 50 GHz.
  • Absolute Power from -70 to +20 dBm.
  • Phase Modulation up to 26.5 GHz.
  • Phase Generate 0 to 90 º (up to 30 kHz)
  • Phase measure 0 to 359.9 º (up to 500 kHz)
  • Distortion 20 hZ to 26.5 GHz.

Common equipment serviced:

DC/LF: Multimeters, Oscilloscopes, LCR Meters, Oscilloscope/meter probes, Power supplies, Loads, Safety Testers, Resistance Meters, clamp meters, Hipots, panel meters, etc.

HF/RF/Microwave Signal Generators, Spectrum analyzers, power meters, function generators, power sensors, and Distortion analyzers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Force

Global Calibration Scope

  • Force gauges : up to 500 lbs class 6 & F weights

Common equipment serviced: Force gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Hygrométrie

Global Calibration Scope

  • Generate: +/-1.4% RH from 10 to 90% RH

Common equipment serviced: RHT Meter/probes, psychrometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Masse / Balance

Global Calibration Scope

  • Scales: up to 500 lbs class 6 & F weights
  • Balances up to 55 kG Class 1&3 Weights

Common equipment serviced: Balances, Scales

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pression / Vide

Global Calibration Scope

  • Measure:Pneumatic -14.6 to 1000 psig
  • Measure: Hydraulic: 10 to 10000 psig

Common equipment serviced: Calibrators, pressure gauges, sensors/transmitters, barometers, pressure sensors, manometers, Etc.

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Température

Global Calibration Scope

  • Measuring range : -195 ºC to 420 ºC w/ SPRT
  • Range of 35 to 500 ºC for IR Thermometers

Common equipment serviced: Temperature baths, chambers, ovens, calibrators, Temperature probes, IR thermometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Couple

Global Calibration Scope

  • 20 ozf-in to 200 ozf-in.
  • 4 lbf-in to 600 lbf ft.

Common equipment serviced: Torque wrenches, screwdrivers, watches

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Temps / Fréquence

Global Calibration Scope

  • Measure and Generate frequencies up to 50 GHz
  • Tachometers up to 100,000 RPM.

Common equipment serviced: Counters, Stopwatches, Timers, frequency generators, tachometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.