Laboratoire de métrologie à
Long Island, New York

HORAIRES D'OUVERTURE

Lun
07:00 - 04:30
Mar
07:00 - 04:30
Mer
07:00 - 04:30
Jeu
07:00 - 04:30
Ven
07:00 - 04:30
Contacts
(631) 563-3520
80 Orville Drive
Suite 115
Bohemia, NY 11716

ACCRÉDITATION

ISO/IEC 17025: 2017

ANSI/NCSL Z540-1-1994

Scope of accreditation
A2LA Cert #3471.01

A2LA Cert #3471.01

ISO/ IEC 17025

ISO/ IEC 17025

ANSI/NCSL Z540-1-1994

ANSI/NCSL Z540-1-1994

DOMAINES TECHNIQUES

Compétence accréditée
Compétence non accréditée
Dimensionnel
Électricité / Magnétisme
Force
Hygrométrie
Mass / Scale
Pressure / Vacuum
Température
Time / Frequency
Couple
Dimensionnel

Dimensionnel

Compétence accréditée

Global Calibration Scope

  • Rulers and Micrometers up to 24
  • Calipers up to 12 “
  • Pins and Dial Indicators up to 2 “
  • Gauge Blocks up to 4”

Common equipment serviced: Hand tools: Calipers, micrometers, indicators, gauge blocks, rulers & tapes

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Électricité / Magnétisme

Électricité / Magnétisme

Compétence accréditée

Global Calibration Scope

  • AC/DC Voltage Generation up to 1100 V
  • Measurements up to 10 kV
  • Electrical temp simulation: RTD, TC
  • Current Generate up to 20 Amps/1025 A (w/ coil)
  • Power (AC+DC) up to 20.9 kW
  • Resistance up to 1.1 TOhms
  • Oscilloscopes up to 2.1 GHz

Common equipment serviced: DC/LF: Multimeters, Oscilloscopes, LCR Meters, Oscilloscope/meter probes, Power supplies, Loads, Safety Testers, Resistance Meters, clamp meters, Hipots, panel meters, etc.

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Force

Force

Compétence accréditée

Global Calibration Scope

  • Force gauges : up to 500 lbs class 6 & F weights

Common equipment serviced: Force Gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Hygrométrie

Hygrométrie

Compétence accréditée

Global Calibration Scope

  • Generate: 11%,33%,75% RH
  • Measure: +/-1.3% RH from 20 to 90% RH
  • Measure: +/-2.1% RH from 80 to 95% RH

Common equipment serviced: RHT Meter/probes, psychrometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Mass / Scale

Mass / Scale

Compétence accréditée

Global Calibration Scope

  • Scales: up to 200 lbs class F weights
  • Balances up to 6 kG Class 1,3,&4 Weight

Common equipment serviced: Balances, Scales

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pressure / Vacuum

Pressure / Vacuum

Compétence accréditée

Global Calibration Scope

  • (-1 to 0) psig
  • (0 to 1) psig
  • (0 to 15) pisg
  • (15 to 30) psig
  • (30 to 500) pisg
  • (500 to 3000) psig
  • (3000 to 5000) psig
  • (0 to 1) inH20

Common equipment serviced: Calibrators, pressure gauges, sensors/transmitters, barometers, pressure sensors, manometers, Etc.

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Température

Température

Compétence accréditée

Global Calibration Scope

  • – Measuring range : -200 ºC to 400 ºC w/ SPRT
  • Range of 35 to 500 ºC w/ blackbody

Common equipment serviced: Temperature baths, chambers, ovens, calibrators, Temperature probes, IR thermometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Time / Frequency

Time / Frequency

Compétence accréditée

Global Calibration Scope

  • Source/measure frequencies from 100 mHz to 50 GHz.
  • Stopwatches .037 sec / day accuracy

Common equipment serviced: Counters, Stopwatches, Timers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Couple

Couple

Compétence accréditée

Global Calibration Scope

Source:

  • 0.5ozf-in to 1000 lbf in.
  • 83 lbf-ft to 600 lbf ft.

Measure:

  • 0.5ozf in to 10 lbf in.
  • 10 lbf in to 1000 lbf in.

Common equipment serviced: Torque wrenches, screwdrivers, watches, Torque Testers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensionnel

Global Calibration Scope

  • Rulers and Micrometers up to 24
  • Calipers up to 12 “
  • Pins and Dial Indicators up to 2 “
  • Gauge Blocks up to 4”

Common equipment serviced: Hand tools: Calipers, micrometers, indicators, gauge blocks, rulers & tapes

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Électricité / Magnétisme

Global Calibration Scope

  • AC/DC Voltage Generation up to 1100 V
  • Measurements up to 10 kV
  • Electrical temp simulation: RTD, TC
  • Current Generate up to 20 Amps/1025 A (w/ coil)
  • Power (AC+DC) up to 20.9 kW
  • Resistance up to 1.1 TOhms
  • Oscilloscopes up to 2.1 GHz

Common equipment serviced: DC/LF: Multimeters, Oscilloscopes, LCR Meters, Oscilloscope/meter probes, Power supplies, Loads, Safety Testers, Resistance Meters, clamp meters, Hipots, panel meters, etc.

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Force

Global Calibration Scope

  • Force gauges : up to 500 lbs class 6 & F weights

Common equipment serviced: Force Gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Hygrométrie

Global Calibration Scope

  • Generate: 11%,33%,75% RH
  • Measure: +/-1.3% RH from 20 to 90% RH
  • Measure: +/-2.1% RH from 80 to 95% RH

Common equipment serviced: RHT Meter/probes, psychrometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Masse / Balance

Global Calibration Scope

  • Scales: up to 200 lbs class F weights
  • Balances up to 6 kG Class 1,3,&4 Weight

Common equipment serviced: Balances, Scales

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pression / Vide

Global Calibration Scope

  • (-1 to 0) psig
  • (0 to 1) psig
  • (0 to 15) pisg
  • (15 to 30) psig
  • (30 to 500) pisg
  • (500 to 3000) psig
  • (3000 to 5000) psig
  • (0 to 1) inH20

Common equipment serviced: Calibrators, pressure gauges, sensors/transmitters, barometers, pressure sensors, manometers, Etc.

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Température

Global Calibration Scope

  • – Measuring range : -200 ºC to 400 ºC w/ SPRT
  • Range of 35 to 500 ºC w/ blackbody

Common equipment serviced: Temperature baths, chambers, ovens, calibrators, Temperature probes, IR thermometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Temps / Fréquence

Global Calibration Scope

  • Source/measure frequencies from 100 mHz to 50 GHz.
  • Stopwatches .037 sec / day accuracy

Common equipment serviced: Counters, Stopwatches, Timers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Couple

Global Calibration Scope

Source:

  • 0.5ozf-in to 1000 lbf in.
  • 83 lbf-ft to 600 lbf ft.

Measure:

  • 0.5ozf in to 10 lbf in.
  • 10 lbf in to 1000 lbf in.

Common equipment serviced: Torque wrenches, screwdrivers, watches, Torque Testers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.