Laboratoire de métrologie à
Hangzhou – China

HORAIRES D'OUVERTURE

Dim
Closed
Lun
08:00 - 17:00
Mar
08:00 - 17:00
Mer
08:00 - 17:00
Jeu
08:00 - 17:00
Ven
08:00 - 17:00
Sam
Closed
Contacts
+86-0571-56830513
Room 219, Building 5,
Heda Creative Park, No.1, No.8 Street,
Qiantang District, Hangzhou,
Zhejiang, China

ACCRÉDITATION

ISO 45001

ISO 19001

ISO 14001

Scope of accreditation

DOMAINES TECHNIQUES

Compétence accréditée
Compétence non accréditée
Dimensionnel
Chimie
Mechanical inspection
Thermal and climatic testing
Time / Frequency
Électricité / Magnétisme
Dimensionnel

Dimensionnel

Compétence accréditée

Global Calibration Scope

  • Gauge block (steel, tungsten carbide, ceramic…): up to 1500 mm
  • Long length (standard tape rules, peripheral gauges…): up to 100 m

Common equipment serviced: Angle instruments, Measuring bench/optical, Depth gauge, Gauge blocks, Height gauges, Micrometers, Length instruments, Limit gauges, Form and surface, Thread gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Chimie

Chimie

Compétence accréditée

Global Calibration Scope

  • Viscosity: kinematic and dynamic, consistometric cup, etc.
  • Conductivity: Electrical (0 μS/cm to 200 mS/cm) and with Certified Reference Material (1,1 μS/cm to 111,3 mS/cm)
  • Gas detector and Gas Concentration : Carbon monoxide, Nitrogen monoxide, Nitrogen dioxide, Oxygen, Total gaseous organic carbon, Dilution apparatus for olfactometry, Sulfur dioxide, Carbon dioxide, Hydrogen sulfide, Benzene, Methane, Ozone, Propane, etc.
  • Refractometry: (1.33 ~ 1.62) nD (refractive index), 0 to 87.6% Brix, etc.

Common equipment serviced: Conductivity meters, Salinity meters, pH meters, Sucrose solutions, Gas detectors and gas concentration, Particle counters, Refractometry instruments, Viscosity instruments

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Mechanical inspection

Mechanical inspection

Compétence accréditée
Thermal and climatic testing

Thermal and climatic testing

Compétence accréditée

Global Scope

  • 3 to 98 %RH
  • -100 to 1250°C

Common equipment serviced: Climatic chamber, Thermostatic chamber, Refrigerator, Freezer, Oven, etc.

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Time / Frequency

Time / Frequency

Compétence accréditée

Global Calibration Scope

  • Tachometer, stroboscope: 1 up to 600 000 RPM
  • Frequency meters, frequency generators, counters: up to 40 GHz

Common equipment serviced: Digital Timers, Frequency Counters, Frequency Meters / Generators, Frequency Standards, Stopwatches, Stroboscopes, Tachometers, Timers, Phasemeter, Standard RPM generators, Synchro-resolvers, Signal generators

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Électricité / Magnétisme

Électricité / Magnétisme

Compétence accréditée

Global Calibration Scope

  • AC Power & Energy: Triphasic active & Active Monophasic f = 50 – 60 Hz, 0,7 W ≤ P ≤ 71 MW, (Wattmeters, Energy analyzers, Power analyzers, Watt-hour meters, Power converters, multifunction calibrators, Sources for meter or relay testing
  • High voltage:
    • DC: 1 kV to 200 kV
    • AC (50 Hz): 1 kV to 175 kV
  • Magnetometers: 0 to 1700 mT…

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensionnel
Chimie
Mechanical inspection
Essais Thermiques et Climatiques
Temps / Fréquence
Électricité / Magnétisme