ANSI/NCSL Z540.3

DOMAINES TECHNIQUES

Compétence accréditée
Compétence non accréditée
Électricité / Magnétisme
Couple
Time / Frequency
Pressure / Vacuum
Dimensionnel
Fiber Optics
Électricité / Magnétisme

Électricité / Magnétisme

Compétence accréditée

Global Calibration Scope

  • 0.1A to 5000A AC & DC
  • Ration Rx:Rs
  • 1mΩ to 1GΩ (CMC 3µΩ to 25µΩ)
  • 1kVrms to 85kVrms @ 60 Hz

Common equipment serviced: Digital Multimeters, Oscilloscope, Power supplies, LCR Meters, Megohmmeter, Insulation Testers, Function Generator, Power Quality, Ohmmeters, Clamp Meter, Standard Resistors, Hipots, High voltage meter

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Couple

Couple

Compétence accréditée

Global Calibration Scope

  • 2.0ozf.in to 2000lbf.ft

Common equipment serviced: Torque sensors,Torque Tools, Torque Testers & Transducers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Time / Frequency

Time / Frequency

Compétence accréditée

Global Calibration Scope

  • 10MHz w/GPS Receiver
  • 1 to 120 000 RPM
  • 55 to 40 000 RPM
  • ± (0 to 19.99) sec/day (CMC 0.037 sec/day)

Common equipment serviced: Frequency Measure, RPM Optical, RPM Mechanical, Stopwatches & Timers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pressure / Vacuum

Pressure / Vacuum

Compétence accréditée

Global Calibration Scope

  • (-15 to 0) psig
  • (1 to 15) psia
  • (0 to 30) psig
  • (30 to 100) psig
  • (100 to 1000) psig
  • (1000 to 5000) psig
  • (5000 to 10 000) psig

Common equipment serviced: Pressure – Measuring Equipment3, Pneumatic (Vacuum & Gage), Hydraulic

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensionnel

Dimensionnel

Compétence accréditée

Global Calibration Scope

  • Diameters external: -up to 3″
  • Lengths: up to 12″

Common equipment serviced: Plug gauges, Pin gauges, Length standards

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Fiber Optics

Fiber Optics

Compétence accréditée

EQUIPMENT TYPES

Fiber optics transmit light signals encoded with data. Trescal calibrates a range of fiber optics including:

 

  • Sources
    • LED
    • LASER
  • Optical
    • Optical Power Meters
    • Optical Time Domain Reflectometers
    • Optical Loss Test Sets
    • Optical Spectrum Analyzers
    • Optical Return Loss Meters
  • Extinction Ratio Meters
  • Polarimeters

CALIBRATION SCOPE

 

  • Power – Source and Measure
    • +30 dBm to -110 dBm (600 to 1750 nm)
  • Wavelength – Source and Measure
    • 600 to 1750 nm
  • Linearity
    • 0 to -110 dB (633 nm, 650 nm, 850 nm, 1300 nm, 1310 nm, 1550 nm and 1625 nm)
  • OTDR Distance
    • 300 ft, 3000 m, 25 km, 50 km, 100 km (Multimode: 300ft and 3000 m only)
  • Optical Return Loss
    • 10 to 65 db (1310 nm and 1550 nm)
  • Fiber Optic Cable Length
    • Single mode: 0 to 300 km
    • Multimode: 0 to 100 km
Électricité / Magnétisme

Global Calibration Scope

  • 0.1A to 5000A AC & DC
  • Ration Rx:Rs
  • 1mΩ to 1GΩ (CMC 3µΩ to 25µΩ)
  • 1kVrms to 85kVrms @ 60 Hz

Common equipment serviced: Digital Multimeters, Oscilloscope, Power supplies, LCR Meters, Megohmmeter, Insulation Testers, Function Generator, Power Quality, Ohmmeters, Clamp Meter, Standard Resistors, Hipots, High voltage meter

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Couple

Global Calibration Scope

  • 2.0ozf.in to 2000lbf.ft

Common equipment serviced: Torque sensors,Torque Tools, Torque Testers & Transducers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Temps / Fréquence

Global Calibration Scope

  • 10MHz w/GPS Receiver
  • 1 to 120 000 RPM
  • 55 to 40 000 RPM
  • ± (0 to 19.99) sec/day (CMC 0.037 sec/day)

Common equipment serviced: Frequency Measure, RPM Optical, RPM Mechanical, Stopwatches & Timers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pression / Vide

Global Calibration Scope

  • (-15 to 0) psig
  • (1 to 15) psia
  • (0 to 30) psig
  • (30 to 100) psig
  • (100 to 1000) psig
  • (1000 to 5000) psig
  • (5000 to 10 000) psig

Common equipment serviced: Pressure – Measuring Equipment3, Pneumatic (Vacuum & Gage), Hydraulic

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensionnel

Global Calibration Scope

  • Diameters external: -up to 3″
  • Lengths: up to 12″

Common equipment serviced: Plug gauges, Pin gauges, Length standards

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Fiber Optics