Laboratoire de métrologie à
Constanta – Romania

HORAIRES D'OUVERTURE

Lun
08:30 - 17:00
Mar
08:30 - 17:00
Mer
08:30 - 17:00
Jeu
08:30 - 17:00
Ven
08:30 - 17:00
Contacts
+40 371 617 319
Sola 62, Parcela A612/2/3,
Lot 2/3/1, Constanța

ACCRÉDITATION

Obțineți servicii de calibrare în laboratorul nostru acreditat din Constanța, cu trasabilitate la standarde internaționale.

Descoperiți acreditările
ISO 9001

ISO 9001

ISO 17025

ISO 17025

DOMAINES TECHNIQUES

Compétence accréditée
Compétence non accréditée
Hygrométrie
Mass / Scale
Dimensionnel
Force
Électricité / Magnétisme
Chimie
Hygrométrie

Hygrométrie

Non-accredited Capabilities

NIR (near infra-red) instruments for the determination of humidity for cereals and oil seeds

Mass / Scale

Mass / Scale

Compétence accréditée

Standard weights class F2 from 1 mg to 20 kg.

Standard weights class M1 from 1 mg to 1000 kg.

NAWI scales from 0.001 kg to 240.000 kg

Dimensionnel

Dimensionnel

Non-accredited Capabilities

Tank radars

Force

Force

Non-accredited Capabilities

Global Calibration Scope

  • Push pull force measuring devices in tension and compression: up to 1 MN
  • Force machine: up to 5 MN (compression) and up to 1 MN (tension)

Common equipment serviced: Dynamometers, Force machines (Tension and/or Compression), Load cell, Force gauges, Strainmeter, Crimping pliers, Charpy testers, Cable tie tools, Press, Retention tools, Wire wrap tools, Spring balance

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Électricité / Magnétisme

Électricité / Magnétisme

Compétence accréditée

Global Calibration Scope

  • AC Power & Energy: Triphasic active & Active Monophasic f = 50 – 60 Hz, 0,7 W ≤ P ≤ 71 MW, (Wattmeters, Energy analyzers, Power analyzers, Watt-hour meters, Power converters, multifunction calibrators, Sources for meter or relay testing
  • High voltage:
    • DC: 1 kV to 200 kV
    • AC (50 Hz): 1 kV to 175 kV
  • Magnetometers: 0 to 1700 mT…

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Chimie

Chimie

Non-accredited Capabilities

Global Calibration Scope

  • Viscosity: kinematic and dynamic, consistometric cup, etc.
  • Conductivity: Electrical (0 μS/cm to 200 mS/cm) and with Certified Reference Material (1,1 μS/cm to 111,3 mS/cm)
  • Gas detector and Gas Concentration : Carbon monoxide, Nitrogen monoxide, Nitrogen dioxide, Oxygen, Total gaseous organic carbon, Dilution apparatus for olfactometry, Sulfur dioxide, Carbon dioxide, Hydrogen sulfide, Benzene, Methane, Ozone, Propane, etc.
  • Refractometry: (1.33 ~ 1.62) nD (refractive index), 0 to 87.6% Brix, etc.

Common equipment serviced: Conductivity meters, Salinity meters, pH meters, Sucrose solutions, Gas detectors and gas concentration, Particle counters, Refractometry instruments, Viscosity instruments

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Hygrométrie

NIR (near infra-red) instruments for the determination of humidity for cereals and oil seeds

Masse / Balance

Standard weights class F2 from 1 mg to 20 kg.

Standard weights class M1 from 1 mg to 1000 kg.

NAWI scales from 0.001 kg to 240.000 kg

Dimensionnel

Tank radars

Force
Électricité / Magnétisme
Chimie