Laboratoire de métrologie à
Cincinnati, Ohio

HORAIRES D'OUVERTURE

Lun
08:00 - 05:00
Mar
08:00 - 05:00
Mer
08:00 - 05:00
Jeu
08:00 - 05:00
Ven
08:00 - 05:00
Contacts
(513) 874-2122
253 Circle Freeway Drive
Cincinnati, OH 45246

ACCRÉDITATION

ISO/IEC 17025 via A2LA

Scope of accreditation
A2LA Cert #1570.01

A2LA Cert #1570.01

ISO 17025

ISO 17025

DOMAINES TECHNIQUES

Compétence accréditée
Compétence non accréditée
Dimensionnel
Time / Frequency
Chimie
Électricité / Magnétisme
Force
Hygrométrie
Pressure / Vacuum
Mass / Scale
Température
Couple
Dureté
Dimensionnel

Dimensionnel

Compétence accréditée

Global Calibration Scope

  • Gauge blocks: -up to 20”
  • Ring gauges: -up to 20”
  • Thread plugs: -up to 12”
  • Tapers: -up to 8”
  • Plug gauges: -up to 11”
  • Length standards: -up to 72”
  • Squares: -up to 18”
  • Thread rings: Up to 7.8”
  • Surface plates: Up to 180”

Common equipment serviced: Gauge blocks, Thread rings, Thread plugs, Plain rings, Plain plugs, Pin gauges, Sand sieve, Length standards, Thread wires, Squares, Surface plates, Angle blocks

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Time / Frequency

Time / Frequency

Compétence accréditée

Global Calibration Scope

  • Timometer 0.039s/day

Common equipment serviced: Stop watches, Timers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Chimie

Chimie

Compétence accréditée

Global Calibration Scope

  • pH (4,7,10)

Common equipment serviced: pH meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Électricité / Magnétisme

Électricité / Magnétisme

Compétence accréditée

Global Calibration Scope

  • High voltage measure: -up to 60kVdc/42kVac
  • DC current: -up to 1000A w/ coil
  • Phase: 10 to 30khz, up to 10°
  • Oscilloscopes: -up to 1.1GHz

Common equipment serviced: Power supplies, LCR meters, Electronic loads, Multimeters, Clamp meters, Oscilloscopes, Shunts, Process calibrators, Hypots, Ohmmeters, Power quality, Thermometers-simulate

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Force

Force

Compétence accréditée

Global Calibration Scope

  • Up to 500lbs

Common equipment serviced: Load cells, Force gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Hygrométrie

Hygrométrie

Compétence accréditée

Global Calibration Scope

  • 3 to 95% HR from 15 °C to 60 °C with humidity generator  and chilled mirror

Common equipment serviced: Hygrometers, Humidity sensor, Temp humidity meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pressure / Vacuum

Pressure / Vacuum

Compétence accréditée

Global Calibration Scope

  • Pneumatic: -14.2 to 1000PSIG
  • Hydraulic: 0 to 10000PSI

Common equipment serviced: Pressure gauges, Pressure indicators, Pressure transducers, Vacuum gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Mass / Scale

Mass / Scale

Compétence accréditée

Global Calibration Scope

  • Balances: -up to 2kg
  • Scales: -up to 2000lbs

Common equipment serviced: Scales, Balances

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Température

Température

Compétence accréditée

Global Calibration Scope

  • Teperature measure: from –38 to 420°C

Common equipment serviced: Ovens, Temp humidity meters, Environmental chambers, Furnaces, Baths, Drywells, Thermocouples, Temperature probes

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Couple

Couple

Compétence accréditée

Global Calibration Scope

  • Torque wrenches: -up to 1000ft-lbs
  • Torque transducers and torque meters: -up to 500lbs

Common equipment serviced: Torque wrenches, Torque drivers, Torque transducers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dureté

Dureté

Compétence accréditée

Global Calibration Scope

  • Indirect HRA, HRC, HRBW, HR15N, HR30N, HR45N, HR15TW, HR30TW, HR45TW

Common equipment serviced: Rockwell Hardness Testers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensionnel

Global Calibration Scope

  • Gauge blocks: -up to 20”
  • Ring gauges: -up to 20”
  • Thread plugs: -up to 12”
  • Tapers: -up to 8”
  • Plug gauges: -up to 11”
  • Length standards: -up to 72”
  • Squares: -up to 18”
  • Thread rings: Up to 7.8”
  • Surface plates: Up to 180”

Common equipment serviced: Gauge blocks, Thread rings, Thread plugs, Plain rings, Plain plugs, Pin gauges, Sand sieve, Length standards, Thread wires, Squares, Surface plates, Angle blocks

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Temps / Fréquence

Global Calibration Scope

  • Timometer 0.039s/day

Common equipment serviced: Stop watches, Timers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Chimie

Global Calibration Scope

  • pH (4,7,10)

Common equipment serviced: pH meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Électricité / Magnétisme

Global Calibration Scope

  • High voltage measure: -up to 60kVdc/42kVac
  • DC current: -up to 1000A w/ coil
  • Phase: 10 to 30khz, up to 10°
  • Oscilloscopes: -up to 1.1GHz

Common equipment serviced: Power supplies, LCR meters, Electronic loads, Multimeters, Clamp meters, Oscilloscopes, Shunts, Process calibrators, Hypots, Ohmmeters, Power quality, Thermometers-simulate

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Force

Global Calibration Scope

  • Up to 500lbs

Common equipment serviced: Load cells, Force gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Hygrométrie

Global Calibration Scope

  • 3 to 95% HR from 15 °C to 60 °C with humidity generator  and chilled mirror

Common equipment serviced: Hygrometers, Humidity sensor, Temp humidity meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pression / Vide

Global Calibration Scope

  • Pneumatic: -14.2 to 1000PSIG
  • Hydraulic: 0 to 10000PSI

Common equipment serviced: Pressure gauges, Pressure indicators, Pressure transducers, Vacuum gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Masse / Balance

Global Calibration Scope

  • Balances: -up to 2kg
  • Scales: -up to 2000lbs

Common equipment serviced: Scales, Balances

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Température

Global Calibration Scope

  • Teperature measure: from –38 to 420°C

Common equipment serviced: Ovens, Temp humidity meters, Environmental chambers, Furnaces, Baths, Drywells, Thermocouples, Temperature probes

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Couple

Global Calibration Scope

  • Torque wrenches: -up to 1000ft-lbs
  • Torque transducers and torque meters: -up to 500lbs

Common equipment serviced: Torque wrenches, Torque drivers, Torque transducers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dureté

Global Calibration Scope

  • Indirect HRA, HRC, HRBW, HR15N, HR30N, HR45N, HR15TW, HR30TW, HR45TW

Common equipment serviced: Rockwell Hardness Testers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.